Permanent Magnet Motor Common Troubleshooting Solutions
No.  | Symptom  | Probable Causes  | Sugguested Remedy  | 
1  | Machine does not start  | Wiring is abnormal, control wiring is incorrect, or the wire contact is not good  | Check wiring  | 
The motor and the VFD parameters do not match  | Adjust the VFP parameters or contact the manufacturer  | ||
Overloaded  | Reduce load  | ||
Motor insulation is too low  | Contact the manufacturer  | ||
Others  | Contact the manufacturer  | ||
2  | The motor has abnormal noise or excessive vibration  | Motor and rotary drum are not concentric  | Find the reason and reinstall  | 
The motor and VFD parameters do not match  | Adjust the VFD parameters or contact the manufacturer  | ||
Overloaded  | Reduce load  | ||
Bearing is short of oil or damages  | Fill lubricating oil or contact the manufacturer  | ||
Others  | Contact the manufacturer  | ||
3  | Motor has too high temperature rise or is smoking  | Overloaded  | Reduce load  | 
The cooling system is not connected with the motor  | Connect the waterway of the cooling system  | ||
Poor circuit contact  | Check wiring  | ||
4  | Bearing is overheated  | Bearing damages  | Contact the manufacturer for replacement  | 
Over- or under-greasing, or grease has impurities  | Adjust or replace  | 